In stock and ready to ship.
This lug door panel (part number 5000173706) is the access door assembly for the connection box lug compartment on Wacker Neuson G-series mobile generators, covering the mechanical lug terminals where output power conductors are landed and secured. It mounts at the lug box location, which houses the mechanical lugs, the lug safety limit switch, and associated wiring for L1, L2, L3, N, and bond bar connections.
According to Wacker Neuson service documentation, the lug compartment door on G70 and G100/G120 machines is equipped with a lug safety limit switch. When this door is opened, the switch trips the main circuit breaker automatically, providing an interlock that prevents accidental contact with energized terminals. A damaged, broken, or missing lug door panel can compromise this safety interlock and should be replaced promptly to restore proper protective function.
This panel corresponds to assembly reference P-5100021100 and is used across the G-series connection box on G70, G100, and G120 platform machines. It is the correct panel for both standard and cold weather configurations within this generator family.
Compatible with the following Wacker Neuson models:
- G 40 / G40
- G 50 / G50
- G 60 / G60
- G 70 / G70
- G 90 / G90
- G 95
- G 100 / G100
- G 110
- G 120 / G120
- G 130
- G 150
- G 180
Genuine Wacker Neuson OEM part, sold by an authorized dealer.